Bulk Detachable Water Meter
INTRODUCTION
Measuring , memorizing and displaying the volume of cold(hot) water passing through the pipeline.
FEATURES
1. Large flow capacity and small pressure lose.
2. Antipollution,Builtin stainless steel strainer can save the installation cost. The measuring mechanism can be removable from the body for checking maintaining and replacing.
3.Selected high quality materials for steady and reliable characteristic.
4.Vacuum sealed register ensures the dial kept from fog and keep reading clear in long-term service.
TECHNICAL DATA
Water meter temperature grade: T30,T50,T70,T90
Pressure grade:MAP10
Pressure loss grade: Δ P63
Upstream disturbance grade:U5
Downstream disturbance grade:D0
MAXIMUM PERMISSIBLE ERROR
a) In the lower zone from Q1 inclusive up to but excluding Q2 is ±5%
b)If the temperature≤30°C, In the upper zone from Q2 inclusive up to and including Q4 is ±2%
If the temperature>30°C, In the upper zone from Q2 inclusive up to and including Q4 is ±3%
Type | Size | L | H | Connecting flange | ||||
Length | Height | φD1 Outside diameter | φD2 Bolt circle diameter | Connecting Bolts | ||||
mm | (n-M) | |||||||
LXLC -50 | 50 | 200 | 261 | 165 | 125 | 4-M16 | ||
LXLC -65 | 65 | 200 | 271 | 185 | 145 | 4-M16 | ||
LXLC -80 | 80 | 225 | 279 | 200 | 160 | 8-M16 | ||
LXLC -100 | 100 | 250 | 289 | 220 | 180 | 8-M16 | ||
LXLC -125 | 125 | 250 | 299 | 250 | 210 | 8-M16 | ||
LXLC -150 | 150 | 300 | 319 | 285 | 240 | 8-M20 | ||
LXLC -200 | 200 | 350 | 346 | 340 | 295 | 8-M20 | ||
LXLC -250 | 250 | 450 | 434 | 405 | 355 | 12-M20 | ||
LXLC -300 | 300 | 500 | 459 | 460 | 410 | 12-M20 | ||
LXLC -400 | 400 | 600 | 630 | 565 | 515 | 16-M24 | ||
LXLC -500 | 500 | 800 | 738 | 620 | 570 | 20-M24 |
Application
Measuring the volume of cold (hot) water passing through the pipeline
Feature
1. Removable element structure, easy installation and maintenance
2. Vacuum sealed register ensures the dial keep free from condensation and keep the reading clear in a
long term service;
3. Selected high quality materials for steady and reliable characteristic;
4. Technical data conform to international standard ISO 4064.
TECHNICAL DATA
Item No | Size | R Flow turndown | Q4 Max Flow | Q3 Nominal Flow | Q2 Transitional Flow | Q1 Min Flow | Min Reading | Max Reading | |
mm | Q3/ Q1 | Q2/ Q1 | m⊃3;/h | m⊃3; | |||||
LXLG-50E | 50 | 100 | 2.5 | 31.25 | 25 | 0.625 | 0.25 | 0.0005 | 999999 |
200 | 6.3 | 0.7875 | 0.125 | ||||||
LXLG-80E | 80 | 100 | 2.5 | 80 | 63 | 1.575 | 0.63 | ||
200 | 6.3 | 2 | 0.315 | ||||||
LXLG-100E | 100 | 100 | 2.5 | 125 | 100 | 2.5 | 1 | ||
200 | 6.3 | 3.15 | 0.5 | ||||||
LXLG-150E | 150 | 100 | 2.5 | 312 | 250 | 6.25 | 2.5 | 0.005 | 999999 |
200 | 6.3 | 7.875 | 1.25 | ||||||
LXLG-200E | 200 | 100 | 2.5 | 500 | 400 | 10 | 4 | ||
200 | 6.3 | 12.6 | 2 |