Features
Segment code screen display, display is intuitive, easy to operate;
Original imported fuel cell oxygen sensor, fast response, high measurement accuracy, good linearity, long calibration period, weak acid resistance, weak alkali resistance;
In the case of explosion-proof, the menu can be set by magnetic pen to facilitate on-site operation;
Menu lock function prevents misoperation and changes instrument parameters, affecting its performance;
High-precision automatic temperature compensation function to eliminate the error caused by temperature change;
It can be calibrated at any point in the whole range without multi-point calibration, which makes calibration easy and convenient;
Measuring range 0.1ppm~21.00% O2;
Explosion-proof grade Exd IIC T6.
Application
Applied to micro or constant oxygen concentration measurement in environment of explosion-proof grades Exd IIC T6.
Technical Parameters
Measuring Principle | Fuel Cell |
Display Mode | Segment display |
Measuring Range | 0~1.00%, 0~21.00% O2 (available in different ranges: micro or constant) |
Measuring Accuracy | 0~1000ppm /1.00% /21.00%≤±1%FS 0~100ppm≤±2%FS 0~10ppm≤±5%FS |
Repeatability | ≤±1%FS |
Response Time | T90≤60S |
4-20mA.DC (non-isolated output, load resistance less than 500Ω at 24V power supply) One-way programmable dry contact passive alarm output, contact maximum capacity 220VAC/2A | |
Power Supply | DC24V±10% 100mA |
Environment Temperature | -10 ~ +50℃ |
Temperature Humidity | <80%RH |
Sample Gas Temperature | 0~40℃ |
Sampling Method | Access type |
Sample Gas Flow | 400 ~ 600ml/min |
Sample Gas Pressure | 80-120kPa, stable pressure atmosphere (absolute pressure) |
Sample gas components | No corrosive gas, dust content < 1mg/Nm3 |
Dimension | 160.5mm×250m×92.5mm (H×W×D) |
Service Life | >24 months (Under normal use conditions) |
Explosion-proof grade | Exd IIC T6 |
Installation method | Wall mounted |
03
Features
Segment code screen display, display is intuitive, easy to operate;
Original imported fuel cell oxygen sensor, fast response, high measurement accuracy, good linearity, long calibration period, weak acid resistance, weak alkali resistance;
In the case of explosion-proof, the menu can be set by magnetic pen to facilitate on-site operation;
Menu lock function prevents misoperation and changes instrument parameters, affecting its performance;
High-precision automatic temperature compensation function to eliminate the error caused by temperature change;
It can be calibrated at any point in the whole range without multi-point calibration, which makes calibration easy and convenient;
Measuring range 0.1ppm~21.00% O2;
Explosion-proof grade Exd IIC T6.
Application
Applied to micro or constant oxygen concentration measurement in environment of explosion-proof grades Exd IIC T6.
Technical Parameters
Measuring Principle | Fuel Cell |
Display Mode | Segment display |
Measuring Range | 0~1.00%, 0~21.00% O2 (available in different ranges: micro or constant) |
Measuring Accuracy | 0~1000ppm /1.00% /21.00%≤±1%FS 0~100ppm≤±2%FS 0~10ppm≤±5%FS |
Repeatability | ≤±1%FS |
Response Time | T90≤60S |
4-20mA.DC (non-isolated output, load resistance less than 500Ω at 24V power supply) One-way programmable dry contact passive alarm output, contact maximum capacity 220VAC/2A | |
Power Supply | DC24V±10% 100mA |
Environment Temperature | -10 ~ +50℃ |
Temperature Humidity | <80%RH |
Sample Gas Temperature | 0~40℃ |
Sampling Method | Access type |
Sample Gas Flow | 400 ~ 600ml/min |
Sample Gas Pressure | 80-120kPa, stable pressure atmosphere (absolute pressure) |
Sample gas components | No corrosive gas, dust content < 1mg/Nm3 |
Dimension | 160.5mm×250m×92.5mm (H×W×D) |
Service Life | >24 months (Under normal use conditions) |
Explosion-proof grade | Exd IIC T6 |
Installation method | Wall mounted |